The upcoming release of the 3rd edition of VDA 19.1 introduces several important updates by strengthening the robustness and consistency of analysis methods.
The core principles remain unchanged, the focus has shifted towards clearer standardisation of particle extraction methods and verification practices.
Key Updates:
- Minimum requirements for verification of cleanliness specifications. A clearer framework is introduced for supplier-customer agreements, removing restrictions on specific methods while ensuring consistency and comparability of results, when the standard methods of inspection cannot be applied.
- Enhancements to Liquid Extraction Methods: Introduction of low-pressure rinsing and defined start parameter adjustments for liquid extraction processes (for big components which require big extraction liquid volume)
- Ultrasonic Extraction – Noise requirements: New requirements for noise levels in ultrasonic baths and defined expectations for measurement and monitoring
- New Dry Extraction Methods Introduced: Brush-vacuuming method and Stamp test method
These additions expand flexibility while maintaining control over repeatability and reliability.
The majority of updates are concentrated in Chapter 8, covering:
- Gravimetric analysis
- Light-optical particle analysis
- SEM/EDX analysis
Training Update
With the release of the new edition, SQM will begin offering:
ID973 – VDA 19.1: Skilled Assistant for Technical Cleanliness – 2 days training
Starting from June 2026
For those already certified:
- A 4-hour training gap will be available
Participation requires submission of the previous certificate number
Do you want more information on this topic? Don’t hesitate to contact us.